Black Control Range

The Black Control Range defines a limit for the calculation of the intersection to black. If black exceeds the limit, the CMY colorants will not be modified and only black will be added linear. Up to the given limit black will be calculated though. A value 0% indicates that only the CMY colorants will be converted and black will be linearized only. The use case proofing requires an exact absolute colorimteric match which means that the limit should be set to 100%. In most other cases a limit of 80% is a good value to reach a smooth transition in the dark colors region.

This entry was posted in Black Generation settings for DeviceLinks, CoPrA4, DeviceLink Profiling, Settings for DeviceLink Profiling. Bookmark the permalink. Trackbacks are closed, but you can post a comment.